International Journal on Magnetic Particle Imaging IJMPI
Vol. 12 No. 1 Suppl 1 (2026): Int J Mag Part Imag
https://doi.org/10.18416/IJMPI.2026.2603039

Proceedings Articles, ID 988

Background-free reconstruction in magnetic particle imaging via differential offset fields

Main Article Content

Penghua Zhai (1) School of Engineering Medicine, Beihang University, Beijing, China; 2) Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People’s Republic of China, Beijing, China), Zhongwei Bian (1) School of Engineering Medicine, Beihang University, Beijing, China;2) Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People’s Republic of China, Beijing, China), Weixin Xu (1) School of Engineering Medicine, Beihang University, Beijing, China; 2) Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People’s Republic of China, Beijing, China), Jie Tian (1) School of Engineering Medicine, Beihang University, Beijing, China; 2) Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People’s Republic of China, Beijing, China), Wei Mu (1) School of Engineering Medicine, Beihang University, Beijing, China; 2) Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People’s Republic of China, Beijing, China)

Abstract

Magnetic particle imaging (MPI) is a promising molecular imaging technique that enables quantitative visualization of the distribution of magnetic nanoparticles (MNPs). Yet, background signal affects the accurate quantitative assessment of MNPs. To suppress background signal, a common practice is to initially measure the background and subtract it during subsequent MNPs signal acquisition. However, frequent background measurements not only reduce imaging efficiency but can also introduce additional noise and repositioning artifacts. Here, we propose a background-free reconstruction method to eliminate dedicated background measurement. Specifically, a pair of differential symmetric offset fields are sequentially applied to excitation field, and the differential signal between two acquisitions yields a pure MNPs response. Simulation results show that the approach significantly enhances imaging quality compared to background measurement.

Article Details

References

T. Knopp and T. M. Buzug, Magnetic particle imaging: an introduction to imaging principles and scanner instrumentation. Springer Science & Business Media, 2012.
[2] M. Straub and V. Schulz, “Joint reconstruction of tracer distribution and background in magnetic particle imaging,” IEEE transactions on medical imaging, vol. 37, no. 5, pp. 1192–1203, 2018.
[3] Q. Wang et al., “Single-sided magnetic particle imaging device with offset field based spatial encoding,” IEEE Transactions on Medical Imaging, 2024.
[4] P. Vogel et al., “Critical Offset Magnetic PArticle SpectroScopy for rapid and highly sensitive medical point-of-care diagnostics,” Nature Communications, vol. 13, no. 1, p. 7230, 2022.
[5] Z. Bian et al., “Phase offset Calibration of Instantaneous Position for Magnetic Particle Imaging,” International Journal on Magnetic Particle Imaging IJMPI, vol. 9, no. 1 Suppl 1, 2023.

Most read articles by the same author(s)

<< < 1 2 3 4 5 6 > >>